In physics, cryogenics is the study of the production and behaviour of materials at very low temperatures.
It is not well-defined at what point on the temperature scale refrigeration ends and cryogenics begins, but scientists assume a gas to be cryogenic if it can be liquefied at or below -150 °C (123.15 K; -238.00 °F). The U.S. National Institute of Standards and Technology has chosen to consider the field of cryogenics as that involving temperatures below -180 °C (93.15 K; -292.00 °F). This is a logical dividing line, since the normal boiling points of the so-called permanent gases (such as helium, hydrogen, neon, nitrogen, oxygen, and normal air) lie below -180 °C while the Freon refrigerants, hydrocarbons, and other common refrigerants have boiling points above -180 °C.
Discovery of superconducting materials with critical temperatures significantly above the boiling point of liquid nitrogen has provided new interest in reliable, low cost methods of producing high temperature cryogenic refrigeration. The term "high temperature cryogenic" describes temperatures ranging from above the boiling point of liquid nitrogen, -195.79 °C (77.36 K; -320.42 °F), up to -50 °C (223.15 K; -58.00 °F), the generally defined upper limit of study referred to as cryogenics.
A person who studies elements that have been subjected to extremely cold temperatures is called a cryogenicist.
Cryogenicists use the Kelvin or Rankine temperature scale, both of which measure from absolute zero, rather than more usual scales such as Celsius or Fahrenheit, with their zeroes at arbitrary temperatures.
Video Cryogenics
Definitions and distinctions
- Cryogenics
- The branches of engineering that involve the study of very low temperatures, how to produce them, and how materials behave at those temperatures.
- Cryobiology
- The branch of biology involving the study of the effects of low temperatures on organisms (most often for the purpose of achieving cryopreservation).
- Cryoconservation of animal genetic resources
- The conservation of genetic material with the intention of conserving a breed.
- Cryosurgery
- The branch of surgery applying cryogenic temperatures to destroy malignant tissue, e.g. cancer cells.
- Cryoelectronics
- The study of electronic phenomena at cryogenic temperatures. Examples include superconductivity and variable-range hopping.
- Cryotronics
- The practical application of cryoelectronics.
- Cryonics
- Cryopreserving humans and animals with the intention of future revival. "Cryogenics" is sometimes erroneously used to mean "Cryonics" in popular culture and the press.
Maps Cryogenics
Etymology
The word cryogenics stems from Greek ???? (cryo) - "cold" + ?????? (genic) - "having to do with production".
Cryogenic fluids
Cryogenic fluids with their boiling point in kelvins
Industrial applications
Liquefied gases, such as liquid nitrogen and liquid helium, are used in many cryogenic applications. Liquid nitrogen is the most commonly used element in cryogenics and is legally purchasable around the world. Liquid helium is also commonly used and allows for the lowest attainable temperatures to be reached.
These liquids may be stored in Dewar flasks, which are double-walled containers with a high vacuum between the walls to reduce heat transfer into the liquid. Typical laboratory Dewar flasks are spherical, made of glass and protected in a metal outer container. Dewar flasks for extremely cold liquids such as liquid helium have another double-walled container filled with liquid nitrogen. Dewar flasks are named after their inventor, James Dewar, the man who first liquefied hydrogen. Thermos bottles are smaller vacuum flasks fitted in a protective casing.
Cryogenic barcode labels are used to mark dewar flasks containing these liquids, and will not frost over down to -195 degrees Celsius.
Cryogenic transfer pumps are the pumps used on LNG piers to transfer liquefied natural gas from LNG carriers to LNG storage tanks, as are cryogenic valves.
Cryogenic processing
The field of cryogenics advanced during World War II when scientists found that metals frozen to low temperatures showed more resistance to wear. Based on this theory of cryogenic hardening, the commercial cryogenic processing industry was founded in 1966 by Ed Busch. With a background in the heat treating industry, Busch founded a company in Detroit called CryoTech in 1966 which merged with 300 Below in 1999 to become the world's largest and oldest commercial cryogenic processing company. Busch originally experimented with the possibility of increasing the life of metal tools to anywhere between 200%-400% of the original life expectancy using cryogenic tempering instead of heat treating. This evolved in the late 1990s into the treatment of other parts.
Cryogens, such as liquid nitrogen, are further used for specialty chilling and freezing applications. Some chemical reactions, like those used to produce the active ingredients for the popular statin drugs, must occur at low temperatures of approximately -100 °C (-148 °F). Special cryogenic chemical reactors are used to remove reaction heat and provide a low temperature environment. The freezing of foods and biotechnology products, like vaccines, requires nitrogen in blast freezing or immersion freezing systems. Certain soft or elastic materials become hard and brittle at very low temperatures, which makes cryogenic milling (cryomilling) an option for some materials that cannot easily be milled at higher temperatures.
Cryogenic processing is not a substitute for heat treatment, but rather an extension of the heating - quenching - tempering cycle. Normally, when an item is quenched, the final temperature is ambient. The only reason for this is that most heat treaters do not have cooling equipment. There is nothing metallurgically significant about ambient temperature. The cryogenic process continues this action from ambient temperature down to -320 °F (140 °R; 78 K; -196 °C). In most instances the cryogenic cycle is followed by a heat tempering procedure. As all alloys do not have the same chemical constituents, the tempering procedure varies according to the material's chemical composition, thermal history and/or a tool's particular service application.
The entire process takes 3-4 days.
Fuels
Another use of cryogenics is cryogenic fuels for rockets with liquid hydrogen as the most widely used example. Liquid oxygen (LOX) is even more widely used but as an oxidizer, not a fuel. NASA's workhorse space shuttle used cryogenic hydrogen/oxygen propellant as its primary means of getting into orbit. LOX is also widely used with RP-1 kerosene, a non-cryogenic hydrocarbon, such as in the rockets built for the Soviet space program by Sergei Korolev.
Russian aircraft manufacturer Tupolev developed a version of its popular design Tu-154 with a cryogenic fuel system, known as the Tu-155. The plane uses a fuel referred to as liquefied natural gas or LNG, and made its first flight in 1989.
Other applications
Some applications of cryogenics:
- Nuclear magnetic resonance (NMR)
NMR is one of the most common methods to determine the physical and chemical properties of atoms by detecting the radio frequency absorbed and subsequent relaxation of nuclei in a magnetic field. This is one of the most commonly used characterization techniques and has applications in numerous fields. Primarily, the strong magnetic fields are generated by supercooling electromagnets, although there are spectrometers that do not require cryogens. In traditional superconducting solenoids, liquid helium is used to cool the inner coils because it has a boiling point of around 4 K at ambient pressure. Cheap metallic superconductors can be used for the coil wiring. So-called high-temperature superconducting compounds can be made to super conduct with the use of liquid nitrogen which boils at around 77 K. - Magnetic resonance imaging (MRI)
MRI is a complex application of NMR where the geometry of the resonances is deconvoluted and used to image objects by detecting the relaxation of protons that have been perturbed by a radio-frequency pulse in the strong magnetic field. This is mostly commonly used in health applications. - Electric power transmission in big cities
It is difficult to transmit power by overhead cables in big cities, so underground cables are used. But underground cables get heated and the resistance of the wire increases leading to waste of power. Superconductors could be used to increase power throughput, although they would require cryogenic liquids such as nitrogen or helium to cool special alloy-containing cables to increase power transmission. Several feasibility studies have been performed and the field is the subject of an agreement within the International Energy Agency.
- Frozen food
Cryogenic gases are used in transportation of large masses of frozen food. When very large quantities of food must be transported to regions like war zones, earthquake hit regions, etc., they must be stored for a long time, so cryogenic food freezing is used. Cryogenic food freezing is also helpful for large scale food processing industries. - Forward looking infrared (FLIR)
Many infra-red cameras require their detectors to be cryogenically cooled. - Blood banking
Certain rare blood groups are stored at low temperatures, such as -165 °C. - Special effects
Cryogenics technology using liquid nitrogen and CO2 has been built into nightclub effect systems to create a chilling effect and white fog that can be illuminated with colored lights. - Manufacturing process
Cryogenic cooling is used to cool the tool tip at the time of machining. It increases the tool life. Oxygen is used to perform several important functions in the steel manufacturing process. - Recycling of Materials
By freezing the automobile or truck tire in Liquid nitrogen, the rubber is made brittle & can be crushed into small particles. These particles can be used again for other items. - Research
Experimental research on certain physics phenomena, such as spintronics and magnetotransport properties, requires cryogenic temperatures for the effects to be observed.
Production
Cryogenic cooling of devices and material is usually achieved via the use of liquid nitrogen, liquid helium, or a mechanical cryocooler (which uses high pressure helium lines). Gifford-McMahon cryocoolers, pulse tube cryocoolers and Stirling cryocoolers are in wide use with selection based on required base temperature and cooling capacity. The most recent development in cryogenics is the use of magnets as regenerators as well as refrigerators. These devices work on the principle known as the magnetocaloric effect.
Detectors
For cryogenic temperature measurement down to 30K, PT-100 sensor (resistance temperature detectors (RTDs)) is used, and for lower than 30K it is required to use Silicon Diode for accuracy. There are also other cryogenic detectors which are used to detect Cryogenic particles.
See also
- Absolute zero
- Coldest temperature recorded on Earth
References
Further reading
- Haselden, G. G. (1971) Cryogenic fundamentals Academic Press, New York, ISBN 0-12-330550-0
Source of the article : Wikipedia